Zoom
Optical smoke detector
  • Optical smoke detector
    Optical smoke detector
  • Emergency push button
    Emergency push button
  • Acoustic alarm device
    Acoustic alarm device
  •  Flush mount double push...
    Flush mount double push...
  • RS rain sensor
    RS rain sensor
  • WS wind sensor
    WS wind sensor
  • CO2
    CO2
  • TH thermostat
    TH thermostat
  • Diagnostic kit (cable+software)
    Diagnostic kit (cable+software)

OPTICAL SMOKE DETECTOR - 36418Q

Smoke detection by infrared light diffusion for Tyndall effect. It is certified according to the UNI EN 54 - 7/9 regulations. Alarm signal through the red led.

RESPONSE TIME 3 sec approx.

VOLTAGE SUPPLY 24 V (min. 10 V, max. 30 V)

TEMPERATURE RANGE -10° + 80° C

DEGREE OF HUMIDITY < 95% MAX AIR

SPEED 10 m/s

DETECTED SURFACE 40 m2

A frequent cleaning, especially in dusty environments, is recommended.

 

EMERGENCY PUSH BUTTON - 41912T

It’s necessary to break the safety strip to open the glass and operate it. Emergency push button allow to control by LEDs the status of the system, reset the control panels and close the window at the end of the emergency.

 

ACOUSTIC ALARM DEVICE - 40892C

Outward self-fed siren 24 V, stainless steel box with polycarbonate cover, sonorous power 115 dB, voltage supply 24 V - 2 A, battery 12 V, 2 Ah. Dimensions: 236x280x99 mm.

 

FLUSH MOUNT DOUBLE PUSH BUTTON - 41019H

Once connected to control panel allows to operate all window for natural ventilation.

 

RS RAIN SENSOR - 40450K

In case of rain, the rain sensor sends the signal for window automatic closing.

 

WS WIND SENSOR - 37185V

It emits a variable signal according to the wind intensity and acts on the control panel as the rain sensors do.

 

CO2 - 41773L

The CO2 sensor, if present, has the priority on the manual control. Suitable for conference and meeting rooms, offices, schools/nurseries, passive and low-energy housing. 2 switch outputs CO2 controlled for 2 stage control, with manual and automatic mode as well as display of switching status. 3x 0–10 V outputs for CO2, temperature and relative humidity. Compatible C-SV, IB-SV only.

 

TH THERMOSTAT - 40675K

The thermostat opens or closes windows when temperature settings are exceeded. Built in on/off switch.

 

DIAGNOSTIC KIT (CABLE + SOFTWARE)- 41853M

In the event of anomalies or installation problems, it is possible to interrogate the C-SV control panels using a special diagnostic USB cable connected to a simple computer. A dedicated software allows you to monitor in real time the operating parameters of the control panel (primary power supply, battery voltage, etc.) and to trace the origin of any faults by reading the associated error code.

 

BATTERIES FOR C-SV AND C-SV IB

40911V - Spare part for C-SV and C-SV IB control panel 4A or 8A, formed by two pieces of 12 V, 4,5 Ah batteries.

41921C - Spare part for C-SV and C-SV IB control panel 13A or 20A, formed by two pieces of 12 V, 9 Ah batteries.